| FEATURES |
|
- Automatic Voltage
Regulation, with Voltage Boost and Buck
- 3 Standby Power Outlets for the Computer, Monitor and Communications
- 3 Surge Protected Outlets for Peripherals
- User changeable battery, low maintenance design
- 3 year manufacturer warranty including battery*
*pro-rata on battery
- Compact power protected workstation format
- 6 protected outlets (3 with UPS Battery Backup)
- Protection network, telephone & modem line
- Automatic Self Test when powered up
- DC Start Capacity (UPS can be activated without AC mains power)
- Bonus Power Guard
- DB9 Communications Connection (RS232)
- Input Circuit Breaker |
| DESCRIPTION |
| This unique Line Interactive
Uninterruptible Power Supply is designed to protect your computer
and computer peripheral equipment from high voltage spikes,
surges, electrical noise/interference, brownouts and blackouts.
As well, providing protection for your telecommunication lines
for modems, fax and networks etc.
The quality engineered design of the FPE UPS PG600VA includes
a built-in AVR (automatic voltage regulator) which ensures
a continuous, stable and safe output voltage to your equipment
while minimising the risks of hardware damage or data loss.
ADDED VALUE BONUS
All FPE UPS's include a "Professional Series" Power
Guard - Model 370-3, the ultimate in automatic electronic
protection (retail value approx $80.00). The Power Guard used
in conjunction with the UPS, doubles the protection for your
equipment.
|
SPECIFICATIONS
|
RECOMMENDED
APPLICATIONS |
Normal
Input Voltage (Mains AC) :
Max Load for UPS power-supplied outlets (3) :
Max Load (3 outlets/Non-UPS) :
Over/Under voltage transfer to battery :
On-battery output voltage :
Output waveform :
Transfer Time :
Transient Energy Absorption A-N, A-E, N-E :
Battery recharge time :
Operating temperature :
Operating Relative Humidity :
Dimensions (mm) :
Net Weight :
Communications Port (Intelligent) :
Warranty :
Indicator Lights :
Battery : 12V 7.2AH (User replaceable)
Intelligent Battery Management :
|
220/230
Vac nominal 50Hz
600VA
220V, 5A 1200W
170-270
220Vac +/- 5%
Computer grade
3-6 ms (Typical) Line Interactive
350 joules <8 hours to 90% capacity
0° - 35°C (32° - 95°F)
0-95% non-condensing
470 x 170 x 76
9 Kg
DB9 (RS 232)
Smart Software Option
3 years (pro-rata on battery)
AC Normal/Battery in use/Battery check/Battery charge
Automatically tests the condition of the battery and alerts
the user to potential problems before the battery wears out.
|
The UPS PG600VA
is designed to protect sensitive equipment on dedicated communication
lines, Computers, Modems |
| NOTES |
- UPS's are load critical. Connecting certain
types of peripherals (eg certain laser copiers and laser
facsimile machines) to any UPS may overload and damage the
UPS, voiding the manufacturers warranty. Please contact
FPE customer service for specific load details if in doubt
with this type of equipment and connection of it to an FPE
UPS.
- PowerGuard does not offer UPS's with
a VA rating below 500VA in our "professional Series"
range. The internationally recommended minimum VA rating
of a UPS used to supply back-up power to a standard Pentium
computer is 500VA.
|
| SPECIFICATIONS
- TELECOMMUNICATION / MODEM LINE RJ11 (DC) |
|
Reaction Time
:
Maximum Amps absorption :
|
1 - 3 nanoseconds
20 000 Amps |
- The back-up times listed are given
as a guideline only. The times have been measured using a standard
Pentium computer. Back-up times will differ, depending on the
power consumption of the computer concerned. |
| SPECIFICATIONS
- NETWORK OR 2ND INCOMING TELECOMMUNICATIONS LINE RJ11 |
- Lower VA models do not have the |
Reaction Time
:
Maximum Amps absorption :
|
1 - 3 nanoseconds
20 000 Amps |
capability of supplying back-up
powerfor an extended time and may be |
| TYPICAL
BACKUP TIME (in minutes) |
working under excessive load when
|
Backup time
is for reference only. Actual duration may vary depending on
temperature, battery conditions and peripherals added.
 |
connected to a Pentium computer.
Permanent damage to the UPS and its batteries can result from